TM 5-1940-277-34 ALTERNATOR REPAIR INSTRUCTIONS (Continued) LOCATION ITEM ACTION REMARKS d. Increase drive speed to 3000 RPM. e. Turn battery selector to 24V. CAUTION Do not exceed 28 vdc on the DC voltmeter.  Damage to alternator rectifiers will result. f. While watching DC voltmeter slowly turn field current rheostat clock- wise until 28 volts are obtained. CAUTION As test stand batteries are charged, reading on DC voltmeter will rise.  Field current rheostat must be turned slightly counterclockwise to maintain 28 volts until battery charging rate has stabilized. g. Turn on master load switch. h. Turn on 50A and 0-25A load switches. 2-89