TM 5-1940-322-24
0047 00
AUXILIARY SWITCH PANEL TO JUNCTION BOX WIRING HARNESS REPLACEMENT (Contd)
REMOVAL (Contd)
9.
Remove ring buoy (3) from mounting brackets (4) and set aside.
10.
Remove two wingnuts (2) from access panel (1) and lower.
11.
Remove four screws (8), seal washers (7), junction box cover (6), and cover seal (9) from junction
box (5).
12.
Remove nut (10) and electrical lead (11) from post (46) and junction box (5).
13.
Remove nut (10) and electrical lead (48) from post (47) and junction box (5).
14.
Remove conduit nut (16), seal ring (15), and collar (14) from fitting (13) and junction box (5).
15.
Disconnect electrical lead (12) from post (46) and remove from junction box (5).
16.
Remove conduit nut (22), seal ring (21), and collar (20) from fitting (19) and junction box (5).
17.
Disconnect electrical lead (17) from post (47) and remove from junction box (5).
18.
Disconnect electrical leads (18), (28), (29), (30), (31), and (32) from bottom junction block (45).
19.
Remove conduit nut (26), seal ring (25), and collar (24) from fitting (23) and junction box (5).
20.
Remove cable (27) from junction box (5).
21.
Disconnect electrical leads (43), (42), (41), (40), (39), and (38) from top of junction block (44).
22.
Remove conduit nut (36), seal ring (35), and collar (34) from fitting (33) and junction box (5).
23.
Remove cable (37) from junction box (5).
INSTALLATION
1.
Install cable (37) in junction box (5).
2.
Connect electrical leads (43), (42), (41), (40), (39), and (38) to top of junction block (44).
3.
Install fitting (33), collar (34), seal ring (35), and conduit nut (36) on junction box (5).
4.
Install cable (27) in junction box (5).
5.
Connect electrical leads (18), (28), (29), (30), (31), and (32) to bottom junction block (45).
6.
Install fitting (23), collar (24), seal ring (25), and conduit nut (26) on junction box (5).
7.
Install electrical lead (17) in junction box (5) and connect electrical lead (17) to post (47).
8.
Install fitting (19), collar (20), seal ring (21), and conduit nut (22) on junction box (5).
9.
Install electrical lead (12) in junction box (5) and connect electrical lead (12) to post (46).
10.
Install fitting (16), collar (15), seal ring (14), and conduit nut (13) on junction box (5).
11.
Install electrical lead (48) in junction box (5) and secure on post (47) with nut (10).
12.
Install electrical lead (11) in junction box (5) and secure on post (46) with nut (10).
13.
Install cover seal (9) and junction box cover (6) on junction box (5) with four seal washers (7) and
screws (8).
14.
Close and secure access panel (1) with two wingnuts (2).
15.
Install ring buoy (3) on mounting brackets (4).
0047 00-4