TM 5-1940-322-24
0123 00
TRANSMISSION OIL PUMP MAINTENANCE (Contd)
CAUTION
Cap or plug all hoses, connections, and openings immediately after
installation. Failure to comply may result in damage to equipment.
NOTE
Both transmission oil pumps are replaced the same way. This
procedure covers the replacement of one transmission oil pump.
Note position of elbow during removal to assist with installation.
REMOVAL
NOTE
Have a container ready to catch transmission oil.
1.
Remove two nuts (1), lockwashers (7), and electrical leads (2) from transmission pressure sending
2.
Remove transmission pressure sending unit (6) from elbow (5) on transmission oil pump (3).
3.
Disconnect transmission oil supply hose (4) from elbow (5) on transmission oil pump (3).
4.
Remove elbow (5) from transmission oil pump (3).
5.
Remove four screws (10), transmission oil pump (3), and gasket (11) from manifold assembly (8) on
transmission housing (9). Discard gasket (11).
CLEANING AND INSPECTION
1.
For general cleaning and inspection instructions, refer to WP 0013 00.
2.
For general transmission inspection, refer to WP 0165 00.
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near heat,
sparks, flame, or other ignition sources. Use mechanical ventilation
whenever product is used in a confined space, heated above
ambient temperatures, or agitated. Keep container sealed when not
in use.
Contact with Skysol 100 may cause skin irritation. Use chemical-
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may cause
irritation, tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact, flush eyes with
large amounts of water for at least 15 minutes or until irritation
subsides. Inhalation may cause irritation to upper respiratory
passages. DO NOT have food or drink in the vicinity. Failure to
comply may result in injury to personnel.
3.
Remove excess sealing compound from elbow (5) with Skysol 100 and dry with cloth.
4.
Remove excess gasket material from transmission oil pump (3) and manifold assembly (8) mating
surfaces with Skysol 100 and dry with cloth.
0123 00-2