TM 5-1940-322-24
0144 00
CAPSTAN, TOW HOOK, AND MOUNTING POST BRACKET MAINTENANCE (Contd)
CLEANING AND INSPECTION
1.
For general cleaning and inspection instructions, refer to WP 0013 00.
WARNING
Skysol 100 solvent is combustible; DO NOT use or store near heat,
sparks, flame, or other ignition sources. Use mechanical ventilation
whenever product is used in a confined space, heated above
ambient temperatures, or agitated. Keep container sealed when not
in use.
Contact with Skysol 100 may cause skin irritation. Use chemical-
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may cause
irritation, tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact, flush eyes with
large amounts of water for at least 15 minutes or until irritation
subsides. Inhalation may cause irritation to upper respiratory
passages. DO NOT have food or drink in the vicinity. Failure to
comply may result in injury to personnel.
2.
Clean all metal parts with Skysol 100 and dry with cloth before inspection.
3.
Inspect tow hook (13), tow hook body (6), quick release lever (3), hook quick release pin (7), and buffer
bracket (10) for damage. Replace if damaged.
4.
Inspect threads on screws (9), (11), (19), and (21), pivot shaft (16), and shoulder bolt (8) for damage.
Replace if damaged.
5.
Inspect spring washer (17) and spring (1) for cracks or damage. Replace if cracked or damaged.
6.
Inspect capstan mounting post bracket (20) and tow hook mounting brackets (18) for damage. Replace
if damaged.
7.
Inspect feed arm (14), collets (24), and rope drum (15) for damage. Replace if damaged.
8.
Inspect capstan gear assembly (22) and needle roller bearings (23) for damage. Replace capstan if
damaged.
0144 00-4