TM 5-5420-202-20-2
FUEL PUMP REPLACEMENT - LEFT FUEL TANK (Sheet 8 of 9)
11.
Position access cover (W) with capacitor
housing adapter (X) up (as shown). Install
new gasket (Y) over fuel tank opening with
holes alined, and using 1/2 inch socket and
wrench, install twelve screws (Z) and
washers (AA). Use torque wrench and tighten
screws (Z) to 50 to 85 lb-in. (6-10 N m).
12.
Using slip joint pliers, install lockwire (AB)
between screws (Z).
13.
Using screwdriver, secure electrical lead (AC)
of housing and capacitor (AD) to adapter (X)
with screw (AE) and lockwasher (AF).
14.
Position capacitor and housing (AD) onto
cover (W). Using screwdriver, install four
screws (AG) and washers (AH) securing
capacitor and housing (AD) to cover (W).
15.
Using slip joint pliers, install lockwire (AJ)
into screws (AG).
Go on to Sheet 9
7-18