TM 5-5420-202-34
FRONT ACCESSORY HARNESS REPLACEMENT (Sheet 9 of 14)
4.
Connect connectors (F) (CKT
516) to IR power packs (G).
5.
Using 7/8 inch wrench, tighten
connectors (F).
6.
Using 7/16 inch socket, install
cushion clamp (H), lockwasher
(J), and screw (K) to secure
wiring harness assembly (A)
between IR power packs (G).
7.
Route wiring harness assembly (A) to bulkhead connector (L), fixed fire extinguisher
relay (M) and air cleaner blower relay (N).
Go on to Sheet 10