TM 5-5420-209-12
Table 2-10. Operator Preventive Maintenance Checks and Services (PMCS) for the Transporter.
Location
Interval
Item To be Inspected
Equipment Is Not
Item to
Procedure
Ready/Available If
Service/Check
1
Before
Mirror
Check mirror configuration. (Should be dual
Assembly
highway type).
Inspect mirror for cracks and broken glass.
Inspect brace, bracket and support arm for
cracks, broken welds, deformation and loose,
broken, or missing hardware.
2
Before
Cab Step
Inspect for cracks, broken welds and jagged
Extension
protrusions.
Filter indicator sight glass
must be obstruction free and
indicator must be visible in
GREEN band. Do not
proceed with PMCS if
indicator is not in GREEN
band.
3
Before
Hydraulic Filter
Check filter indicator position. (Should be in
Indicator is NOT in
Assembly
GREEN band).
green band.
Inspect filter housing for cracks and leakage.
Class II or III leak noted.
Inspect lines for cracks, compression and
Class II or III leak noted.
leakage.
4
Before
Power Take Off
Check lever operation. (Should transfer power
Levers do not function
(PTO) Levers
to gear pump easily).
properly.
Inspect for deformation.
5
Before
Hydraulic
Check valve operation. (Valve should engage
Any valve does NOT
Console
item indicated).
engage item indicated.
Control Valves
Inspect valves for cracks, leakage and loose,
Class II or III leak noted.
broken or missing hardware.
Inspect valves hydraulic lines for compression,
Class II or III leak noted.
leakage and cracks.
6
Before
Floodlight
Check switch operation. (Should turn on both
Master Switch
floodlights).
Inspect switch for loose or bare wires.
Inspect data plate for legibility.
7
Before
Remote
Check throttle operation. (Should
Throttle
increase/decrease engine RPM easily).
Assembly
Inspect throttle, cable and retaining clamps for
(M945)
compression, kinks, and deformation.
2-20
Item
N o .