2-8. Cable Tensioner Assembly.
This task covers:
Repair
INITIAL SETUP
Tools
General Mechanics Tool Kit
(NSN 5180-00-177-7033)
Materials/Parts
Compound, Sealing (Item 1, Appendix B)
Solvent, Dry Cleaning (Item 2, Appendix B)
Rags, Wiping (Item 5, Appendix B)
Equipment Condition:
Cable Tensioner Assembly removed
(TM 5-5420-209-12).
a. Repair. (figure 2-1)
WARNING
Dry cleaning solvent, PD-680, used to dean parts is potentially dangerous to personnel and
property. Avoid repeated and prolonged skin contact. Do not use near open flame or exces-
sive heat. Flash point of solvent is 100 F-138F (380 C-600 C).
CAUTION
Thoroughly dean cable tensioner with solvent prior to disassembly to prevent contamination
and equipment damage.
NOTE
Screws are installed with sealing compound and may require heating for removal.
(1) Remove locknut(1), nut (2), spring washers (3) and washers(4).
(2) Remove nut (5), lockwasher (6), bolt(7), shaft(8), and lube fitting (9).
2 - 4