ENGINE GENERATOR REGULATOR REPLACEMENT
ENGINE GENERATOR REGULATOR MOUNTING BRACKET REPLACEMENT

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  14    15    16    17    18  19  20    21    22    23    24  
img
. .
TM 5-5420-226-20-3
ENGINE GENERATOR REGULATOR REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
1. Place engine generator regulator(A)
in position on mounting bracket (B).
2. Using screwdriver, tighten four screws
(C) securing engine generator regulator
(A) to mounting bracket (B).
3. Using spanner wrench, connect two electrical connectors(D) to engine generator
regulator (A).
4. Place ground(E) and new lockwashers (F) in position on engine generator regulator
(A).
5. Using screwdriver, tighten screw (G) securing ground (E) and lockwashers(F)to
engine generator regulator (A).
6. Place other end of ground(E), screw (H), and two lockwashers (J) in position on hull.
7. Using socket, tighten screw (H) securing ground (E) to hull.
8. Replace access plate (page 17-9).
9. Check generator for operation (TM 5-5420-226-10).
End of Task
TA168670