MASTER CONTROL PANEL REPAIR - Continued
MASTER CONTROL PANEL REPAIR - Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  71    72    73    74    75  76  77    78    79    80    81  
img
.
TM 5-5420-226-20-3
MASTER CONTROL PANEL REPAIR (Sheet 37 of 73)
Circuit Breaker Replacement (Sheet 5 of 7)
REMOVAL; CIRCUIT BREAKER (F):
1.
Using flat-tip screwdriver on screw
(A) and 11/32 inch wrench on nut (B),
remove four screws (A), lockwashers
(C), and nuts (B) securing connector
(D) to panel.
2.
Remove connector (D) from panel and
position aside.
Using fingers, remove two electrical
connectors from rear of circuit breaker
(E) by pulling out.
Using cross-tip screwdriver, remove
4.
two screws (F) and lockwashers (G)
securing circuit breaker (E) to panel.
Remove circuit breaker(E).
5.
Go on to Sheet 6
TA168725