MASTER CONTROL PANEL REPAIR - Continued
MASTER CONTROL PANEL REPAIR - Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  72    73    74    75    76  77  78    79    80    81    82  
img
.
TM 5-5420-226-20-3
MASTER CONTROL PANEL REPAIR (Sheet 38 of 73)
Circuit Breaker Replacement (Sheet 6 of 7)
INSTALLATION; CIRCUIT BREAKER (F) :
1.
Place circuit breaker (A) in position on panel.
2.
Using cross-tip screwdriver, install two screws (B) and lockwashers (C).
3.
Apply silicone compoud to two male electrical connectors on circuit breaker (A).
4.
Using fingers, connect two electrical connectors in rear of circuit breaker (A) by
pushing in.
5.
Position connector (D) to panel.
Using flat-tip screwdriver on screws and
6.
wrench on nuts, install and secure four
screws (E), lockwashers (F), and nuts
(G).
Go on to Sheet 7
TA168726
10-75