MASTER CONTROL PANEL REPAIR - Continued
MASTER CONTROL PANEL REPAIR - Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  97    98    99    100    101  102  103    104    105    106    107  
img
.
TM 5-5420-226-20-3
MASTER CONTROL PANEL REPAIR (Sheet 63 of 73)
Master Battery Wiring Harness Replacement (Sheet 4 of 4)
3.
Apply silicone compound to all male connectors of the master battery wiring harness.
Connect electrical connector (circuit 76) (E).
4.
Connect lead (circuit 54A) to fuel shutoff switch (F).
5.
Connect two leads (circuit 459A), one to master battery switch (G) and
6.
one to master battery indicator light (H).
Connect lead (circuit 486) to manifold pre-heat circuit breaker (J).
7.
Position connector (K) onto panel.
8.
Using flat-tip screwdriver on screw (L) and 11/32 inch wrench on nut (M), install four
9.
screws (L), new lockwashers (N), and nuts (M) to secure connector (K) to panel
Install panel in vehicle (page 10-36).
10.
End of Task