MASTER CONTROL PANEL REPAIR - Continued
MASTER CONTROL PANEL REPAIR - Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  99    100    101    102    103  104  105    106    107    108    109  
img
TM 5-5420-226-20-3
MASTER CONTROL PANEL REPAIR (Sheet 65 of 73)
Master Control Panel Wiring Harness Replacement (Sheet 2 of 7)
Disconnect electrical connector (circuit 14) from starter switch (K).
5.
6. Disconnect electrical connector (circuit 14) (L).
7.
Remove lead (circuit 37) from utility outlet circuit breaker (M).
Remove lead (circuit 27) from gage circuit breaker (N).
8.
Disconnect electrical connector (circuit 15) and (circuit 459) from master battery switch
9.
(P).
TA168753
Go on to Sheet 3
10-102