INSTRUMENT PANEL CLUSTER ASSEMBLY REPAIR - Continued
INSTRUMENT PANEL CLUSTER ASSEMBLY REPAIR - Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  115    116    117    118    119  120  121    122    123    124    125  
img
.
TM 5-5420-226-20-3
INSTRUMENT PANEL CLUSTER ASSEMBLY REPAIR (Sheet 5 of 23)
Battery Generator Indictior Replacement (Sheet 2 of 2)
2. Place indicator (A) in position in panel.
3. Place mounting bracket (B) in position on indicator (A).
4. Using wrench, install two nuts (C)
lockwashers (D) securing indicator (A) and
mounting bracket (B) on panel.
5. Connect lead (circuit 27) to rear of indicator (A) by pushing in.
6. Install panel in vehicle (page 10-112).
End of Task
TA168769