HIGH VOLTAGE IR POWER SUPPLY AND SHOCK MOUNT ASSEMBLY REPLACEMENT
HIGH VOLTAGE IR POWER SUPPLY AND SHOCK MOUNT ASSEMBLY REPLACEMENT- Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  150    151    152    153    154  155  156    157    158    159    160  
img
TM 5-5420-226-20-3
HIGH VOLTAGE IR POWER SUPPLY AND SHOCK MOUNT ASSEMBLY REPLACEMENT
(Sheet 2 of 6)
REMOVAL:
1. Using 7/8 inch wrench, disconnect
cable (A) from power supply (B).
2. Using 1 inch wrench, disconnect
cable (C) from power supply (B).
3. Using 1/2 inch socket and extension remove four screws (D) and washers (E)
securing power supply (B) to mounting pad (F).
4.
Remove clamps (G).
5.
Remove power supply (B) from mounting pads (F).
6.
Remove four lockwashers (H).
Go on to Sheet 3
TA168804
10-153