HIGH VOLTAGE IR POWER SUPPLY AND SHOCK MOUNT ASSEMBLY REPLACEMENT- Continued
FIRE EXTINGUISHER SOLENOID RELAY REPLACEMENT

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  154    155    156    157    158  159  160    161    162    163    164  
img
TM 5-5420-226-20-3
HIGH VOLTAGE IR POWER SUPPLY AND SHOCK MOUNT ASSEMBLY REPLACEMENT
(Sheet 6 of 6)
Position four lockwashers (Q) onto mounting pads (R).
11.
12. Position assembled power supply (K) onto mounting pad (R) inside vehicle.
13.
Install screw (S) through lockwasher
(T), ground strap (M), lockwasher (U),
and bracket (B).
14.
Using 1/2 inch socket and
an 5 inch extension, tighten
screw (S) into mounting pad (R).
15.
Position clamp (V) on cable (W).
16.
Install screw (X) through lockwasher
(Y), clamp (V), and bracket (B).
17.
Using 1/2 inch socket and
extension, tighten screw (X).
18.
Using steps 16 and 17, except
omitting clamp (V), install
remaining two screws (X)
and new lockwashers (Y) securing
bracket (B) and mounting pads (R).
19.
Using 1 inch wrench, install
connector on cable (Z) to
power supply (K).
20.
Using 7/8 inch wrench, install connector on cable (AA) to power supply (K).
Install access plate (page 17-9).
21.
End of Task
TA168808