MASTER RELAY MOUNTING PLATE AND BRACKET REPLACEMENT
AIR CLEANER MOTOR SOLENOID RELAY REPLACEMENT

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  159    160    161    162    163  164  165    166    167    168    169  
img
.
TM 5-5420-226-20-3
MASTER RELAY MOUNTING PLATE AND BRACKET REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
1.
Using hammer, tap eight new nuts (A) into plate (B).
2.
Place plate (B) in position on hull floor.
Using 9/16 inch socket, install two screws (C) and lockwashers (D) securing plate (B)
3.
to hull floor.
Using 9/16 inch socket, install two screws (E), lockwashers (F), and flat washers (G)
4.
securing plate (B) to hull floor.
Place two washers (H) in position on plate (B).
5.
Place mounting bracket (J) in position on plate (B).
6.
Using 1/2 inch socket, install two screws (K) and lockwashers (L) securing
7.
mounting bracket (J) to plate (B).
8.
Install master relay assembly (page 10-139).
End of Task