AIR CLEANER MOTOR SOLENOID RELAY REPLACEMENT - Continued
FUEL SHUTOFF AND PERSONNEL HEATER CIRCUIT BREAKERS REPLACEMENT - Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  162    163    164    165    166  167  168    169    170    171    172  
img
.
TM 5-5420-226-20-3
FUEL SHUTOFF AND PERSONNEL HEATER CIRCUIT BREAKERS REPLACEMENT (Sheet 1 of 2)
TOOLS:
2 in. cross-tip screwdriver
PRELIMINARY PROCEDURE:
Remove access plate from floor at commander's station
(page 17-9).
REMOVAL:
1.
Disconnect electrical leads (A) from circuit breaker (B).
2. Using screwdriver, remove two
screws (C) and lockwashers (D)
securing circuit breaker (B)
to mounting plate (E).
3.
Remove circuit breaker (B) from mouting plate (E).
TA168817
10-165