HEU MAIN POWER WIRING HARNESS DISCONNECT

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  378    379    380    381    382  383  384    385    386    387    388  
img
.
TM 5--5420--226--20-3
TM 5-5420-202-3420-3
TM 5 5420 202
POWER/MASTER CONTROL PANEL HARNESS REPLACEMENT (Sheet 8 of 8)
Follow branch of harness assembly (A)
11.
to back side of basket disconnect.
Using spanner wrench, connect bottom
12.
connector (R) (CKT 400, 459, 10) at back
side of basket disconnect.
Install voltage regulator assembly (TM
13.
5-5420-226-20).
Install subfloor access cover under
14.
commander's periscope stowage box
(TM 5-5420-226-20).
Install commander's periscope stowage
15.
box (TM 5-5420-228-24).
16.
Install sub floor access cover under
commander's seat (TM 5-5420-226-20).
17.
Install three battery ground straps
(TM 5-5420-226-20).
End of Task