NIGHT VIEWER POWER HARNESS REPLACEMENT- Continued
NIGHT VIEWER POWER HARNESS REPLACEMENT- Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  432    433    434    435    436  437  438    439    440    441    442  
img
TM 5-5420-226-20-3
NIGHT VIEWER POWER HARNESS REPLACMENT (Sheet 6 of 7)
Route lead (A) along existing har-
nesses to centermost.
Install clamp (H) onto lead (A).
Using socket, install screw (J) and new
lockwasher (K) to secure clamp (H),
two ground leads (L and M), and new
lockwasher (N) to centerpost.
Route short leg of harness (P) along
9.
commander's overhead crossbeam (Q)
and connect it to stowage connector
(R).
Insert harness into two spring clips (S).
10.
11.
Install clamp (T) onto harness (P).
Using socket, install screw (U) and
12.
new lockwasher (V) to secure clamp
(T), periscope ground lead (W), and
lockwasher (X) to commander's over
head crossbeam (Q).
Go on to Sheet 7