• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
RESERVOIR QUADRANT BLOWER MOTOR REPAIR (Sheet 1 of 4)
RESERVOIR QUADRANT BLOWER MOTOR REPAIR (Sheet 3 of 4)

Launcher Hydraulics System M48A5/M60A1 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 Page Navigation
  557    558    559    560    561  562  563    564    565    566    567  
img
.
TM 5-5420-228-24
RESERVOIR QUADRANT BLOWER MOTOR REPAIR (Sheet 2 of 4)
6.
Using screwdriver, remove four screws (L) and lockwashers (M).
7.
Manually separate commutator head (H), fan head (J), frame (K), two gaskets (N), armature
(P), two bearings (0), and seal assembly (R). Throw gaskets (N) and seal assembly (R) away.
8.
Using screwdriver, remove five screws (S) and lockwashers (T).
Manually remove capacitor (U) and cable assembly (V).
9.
10.
Using screwdriver, remove four screws (W).
Manually remove receptacle assembly (X) and gasket (Y). Throw gasket (Y) away.
11.
12.
Using adjustable wrench, remove pipe plug (Z).
CLEANING AND INSPECTION:
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. To prevent
personal injury, wear protective goggles and gloves and use only in a
well-ventilated area. Avoid contact with skin, eyes, and clothes and
don't breathe vapors. Do not use near open flame or excessive heat.
The flash point for Type #1 Dry Cleaning Solvent is 100°F (38°C)
and for Type #2 is 138°F (50°C). If you become dizzy while using
cleaning solvent, get fresh air immediately and get medical aid. If
contact with eyes is made, wash your eyes with water and get
medical aid immediately.
Go on to Sheet 3
TA251657
4-5






Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.