ACCESSORIES CONTROL BOX REPAIR (Sheet 5 of 8)
ACCESSORIES CONTROL BOX REPAIR (Sheet 7 of 8)

Launcher Hydraulics System M48A5/M60A1 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 Page Navigation
  565    566    567    568    569  570  571    572    573    574    575  
img
TM 5-5420-228-24
ACCESSORIES CONTROL BOX REPAIR (Sheet 6 of 8)
NOTE
Appl y silicone compound to
all rubber electrical connec-
tors before installation.
11.
Manually connect electrical connector
(CKT 137) (A) to circuit breaker (A).
12.
Manually connect electrical connector
(CKT 465) (AA) to circuit breaker (B).
13.
Manually connect electrical connector
(CKT 894) (AB) to circuit breaker (C).
14.
Manually connect electrical connector
(CKT 625) (AC) to circuit breaker (D).
Place one end of cable assembly
15.
(CKT 159) (AD) on remaining terminal of
circuit breaker (L).
16.
Using flat-tip screwdriver, install
screw (AE) and lockwasher (AF) to
circuit breaker (L).
Place remaining end of cable assembly
17.
(CKT 159) (AD) on rear of switch
assembly (H).
18.
Using 7/16 inch wrench, install nut (AG),
flat washer (AH), and lockwasher (AJ)
to switch assembly (H).
TA251665
Go on to Sheet 7
4-13






Western Governors University