SMOKE GRENADE DISCHARGER WIRING HARNESS ASSEMBLY REPLACEMENT (Sheet 1 of 2)
SMOKE GRENADE DISCHARGER REPLACEMENT (Sheet 1 of 2)

Launcher Hydraulics System M48A5/M60A1 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 Page Navigation
  642    643    644    645    646  647  648    649    650    651    652  
img
TM 5-5420-228-24
SMOKE GRENADE DISCHARGER WIRING HARNESS ASSEMBLY REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
WARNING
Make sure there are no smoke
grenades in dischargers. Acci-
dental firing of grenade could
hurt or kill you.
Connect electrical connector (A)
1.
of harness (B) to headlight adapter
receptacle (C). Connect electrical
connector (D) to discharger unit recep-
tacle (E).
Put clamp (F) on harness (B).
2.
Using socket and ratchet, install and
3.
tight-en screw (G) and lockwasher (H)
to secure clamp (F) and harness (B)
to headlamp guard (J).
Per form smoke grenade launcher
4.
functional check (TM 5-5420-202-20).
End of Task