• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
SMOKE GRENADE DISCHARGER BRACKET DUMMY RECEPTACLE REPLACEMENT (Sheet 1 of 2)
SMOKE GRENADE STOWAGE BOX REPLACEMENT (Sheet 1 of 1)

Launcher Hydraulics System M48A5/M60A1 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 Page Navigation
  646    647    648    649    650  651  652    653    654    655    656  
img
TM 5-5420-228-24
SMOKE GRENADE DISCHARGER BRACKET DUMMY RECEPTACLE REPLACEMENT
(Sheet 2 of 2)
INSTALLATION:
WARNING
Make sure there are no smoke
grenades in dischargers. Acci-
dental firing of grenade could
hurt or kill you.
NOTE
Installation procedures are the
same for both the left and right
dummy receptacles.
Put dummy receptacle (A) and new
1.
gasket (B) in position on back of discharger
bracket (C).
Using screwdriver, secure receptacle (A)
2.
and gasket (B) to discharger bracket (C)
with four screws (D) and new lockwashers (E).
Connect electrical connector (F) of
3.
discharger harness (G) to receptacle (H)
at back of discharger (J).
Per form smoke grenade launcher
4.
functional check (TM 5-5420-202-20).
End of Task
TA251749
4-101






Western Governors University