TM 5-5420-280-10
0022 00
TRANSPORT OF PALLET ON GROUND (Contd)
2. Lower steering axles (1) as follows:
a.
Position selector valve lever (6) in POSITION 3 or pointing down and
move control valve lever (3) to POSITION B or right of center.
WARNING
Do not crawl under or place hands or arms under pallet
until support wheel retaining pins are installed. Failure
to comply may result in injury or death to personnel.
CAUTION
Operating pressure range of hydraulic pump is 2,611
psi (180 bar) to 3,408 psi (235 bar). If pressure on gage
reaches 3,626 psi (250 bar), stop and check for
obstructions, such as support wheel retaining pins
inadvertently left in place. Do not exceed 3,626 psi (250
bar), or damage to equipment may result.
b.
Install pump handle on pump lever (4) and operate hydraulic pump (5)
until steering axles (1) are fully lowered (pallet frame is raised off ground
or dunnage).
3. Lower fixed axles (2) as follows:
a.
Position selector valve lever (6) in POSITION 2 or pointing up and move
control valve lever (3) to POSITION B or right of center.
WARNING
Do not crawl under or place hands or arms under pallet
until support wheel retaining pins are installed. Failure
to comply may result in injury or death to personnel.
CAUTION
Operating pressure range of hydraulic pump is 2,611
psi (180 bar) to 3,408 psi (250 bar). If pressure gage
reaches 3,626 psi (250 bar), stop and check for
obstructions, such as support wheel retaining pins
inadvertently left in place. Do not exceed 3,626 psi (250
bar), or damage to equipment may result.
b.
Install pump handle on pump lever (4) and operate hydraulic pump (5)
until fixed axles (2) are fully lowered (pallet frame is raised off ground or
dunnage).
0022 00-2