TRANSFER VALVE, OPEN POSITION
CHARGING PALLET BATTERIES USING CBT

TM-5-5420-280-10 Rapidly Emplaced Bridge (REB) NSN: 5420-01-481-3959 Manual
Page Navigation
  253    254    255    256    257  258  259    260    261    262    263  
TM 5-5420-280-10
0026 00
OPERATION OF CBT BACK-UP POWER FOR BRIDGE LAUNCH OR RETRIEVAL
(Contd)
12. Close transfer valve (3), by turning lever (1) until pointing to the left, once oil
level in sight gauge (2) reaches mark 1, 2, or 3 as determined in step 10.
2
1
3
TRANSFER VALVE, CLOSED POSITION
13. Move HIGH IDLE switch (4) to ON position and complete launch or retrieval.
Refer to WP 0016 00 or WP 0020 00.
4
14. Switch from CBT back-up power to LPU. Refer to WP 0015 00.
NOTE
Oil level in auxiliary reservoir sight gauge will take 24
hours or more to drain back to pallet main reservoir.
15. After completing launch or retrieval, check oil level in pallet main reservoir.
Refer to WP 0007 00.
END OF WORK PACKAGE