TM 5-5420-280-10
0042 00
Preventive Maintenance Checks and Services (PMCS)
for CBT LHS (Contd).
NOT FULLY
ITEM
ITEM TO
MISSION
INTERVAL
PROCEDURE
NO.
CHECK/SERVICE
CAPABLE IF:
10
During
HOOK ARM
a. Move HOOK ARM switch to LOAD
a. Cylinder arms
SWITCH (2),
and hold until hook arm cylinders are
will not operate.
MAIN FRAME
extended approximately 6 in. (15 cm). If
switch (1), and
not, use manual operation. Refer to
cylinder (3)
b. Move MAIN FRAME switch to LOAD b. Main frame will
and hold until main frame is in stowed not move to stowed
position. If not, use manual operation.
position.
c. Move HOOK ARM switch to LOAD
c. Hook arm will not
and hold until hook arm is in stowed
move to stowed
position. If not, use manual operation.
position.
1
2
3
0042 00-8