TM 5-5420-280-10
0042 00
Preventive Maintenance Checks and Services (PMCS)
for CBT LHS (Contd).
NOT FULLY
ITEM
ITEM TO
INTERVAL
PROCEDURE
MISSION
NO.
CHECK/SERVICE
CAPABLE IF:
14
After
Tube
a. Visually check tube assemblies for
a. Cracked or
assemblies (1)
cracks, kinks, and leaks.
kinked tubes impair
and hoses (2)
operation or result
in Class III leaks.
b. Visually check hoses for leaks.
b. Any Class III
leaks are detected.
1
2
1
2
15
After
Cylinders (3)
Visually check lift cylinders for leaks,
Any Class III leaks
and (4)
damage, or missing hardware.
are detected or
cylinders are
damaged.
4
3
0042 00-10