TM 5-5420-280-10
0043 00
Preventive Maintenance Checks and Services (PMCS) for Pallet (Contd).
NOT FULLY
ITEM
ITEM TO
INTERVAL
PROCEDURE
MISSION
NO.
CHECK/SERVICE
CAPABLE IF:
17
Before
Launch
a. Check hydraulic lines for damage, or
a. Lines are not
boom (2), launch loose mounting hardware.
secured properly.
boom locks (3),
b. Check hydraulic lines for leaks.
b. Any Class III leak
and retaining
is noted.
pins (1)
c. Check launch boom locks for damage
c. Launch boom
or if retaining pins are missing.
locks are damaged
or retaining pins are
missing.
1
2
3
18
Before
Pallet hold-
a. Check both hold-down bars for
down bars (4),
damage or missing parts. Ensure hold-
shoring
down bars (4) are tight.
pads (6), and
KA3 and KA4
b. Check to see both shoring pads are
limit switches
present, secured, and aligned as
(5)
marked.
4
5
6
19
Before
Bearing shaft
a. Check for damage, loose or missing
a. Any damage,
manifold (9),
hardware, or leakage.
loose or missing
potentiometer (8),
hardware, or Class
lever (7), and
III leaks noted.
winch wire rope
roller (10)
0043 00-10