TM 5-5420-280-10
0048 00
PALLET MAINTENANCE PROCEDURES (Contd)
A-FRAME PIN GUIDE CHANNELS
1. Using clean rags and solvent, clean two guide channels (1) and wipe dry. Refer
to items 1 and 7, WP 0052 00.
2. Apply a light coat of grease to inside edge of two guide channels (1). Refer to
items 4 and 5, WP 0052 00.
1
RIGHT AND LEFT REMOTE CONTROL LEVER RELEASES
1. Using clean rags and solvent, clean levers (2) and (3) and wipe dry. Refer to
items 1 and 7, WP 0052 00.
2. Apply a light coat of grease to hinge points on levers (2) and (3). Refer to items
4 and 5, WP 0052 00.
2
3
LIMIT SWITCHES
1. Using clean rags and solvent, clean flexible rods on limit switches KA1 (5),
KA2 (6), KA3 (7), and KA4 (8), and three rollers on limit switches on KA5 (4),
KA6 (9), and KA8 (10). Refer to items 1 and 7, WP 0052 00.
NOTE
Do not oil flexible rods on limit switches KA1 through
KA4.
2. Apply a small amount of lubricating oil to rollers on limit switches KA5 (4),
KA6 (9), and KA8 (7).
0048 00-8