MEASURE VOLTAGE INPUT
Electrical Troubleshooting Example Using RCU-continued

TM-5-5420-280-23-P Rapidly Emplaced Bridge (REB) NSN: 5420-01-481-3959 Manual
Page Navigation
  62    63    64    65    66  67  68    69    70    71    72  
TM 5-5420-280-23&P
0004 00
INTRODUCTION TO TROUBLESHOOTING (Contd)
(11) MEASURE DIGITAL OUTPUT
(a) Press OUTPUTS [F2] to select the function for measuring an output.
(b) Press DIGITAL [F2] to measure digital output.
(c) Browse in the list for the different digital outputs using UP/DN. For every channel, the
following is shown:
Channel type
Pin number
Channel name
Measured value
(d) To return to the previous menu, press ESC.
g. Electrical Troubleshooting Example Using RCU
(1) Remove RCU from stowage box and connect to receptacle on electrical control box. Refer to
TM 5-5420-280-10.
(2) Unlatch and open control valve cover to check solenoid lights.
(3) Turn on pallet main power switch. Refer to TM 5-5420-280-10.
(4) RCU (LCD screen) will show TURN ON RCU. Press F1 (OK).
(5) Press ESC to change LCD screen to show MODE.
(6) Press UP/DN button to change LCD screen to show MEASURE. Press F1 INPUTS.
0004 00-5