ADJUSTMENT - TM-5-5420-280-23-P0262
BRIDGE CROSSFORCE COUPLING BUMPERS REPLACEMENT

TM-5-5420-280-23-P Rapidly Emplaced Bridge (REB) NSN: 5420-01-481-3959 Manual
Page Navigation
  223    224    225    226    227  228  229    230    231    232    233  
TM 5-5420-280-23&P
0024 00
BRIDGE UPPER COUPLING LOCK LEVER, RECEPTACLE, AND LOCKING MECHANISM
MAINTENANCE (Contd)
3.60 in.
(9.14 cm)
8
1.70 in.
(4.32 cm)
0.12 in.
(3.04 mm)
5
LOCK POSITION
10
11
9
NOTE
Perform adjustment with bridge halves coupled.
6. Check distance from upper crossforce couplings (2) to center of lock lever (5). There must be 2.09 in.
(5.3 cm) at this point.
7. Check clearance between lock lever pin (5) and locking point with lock lever (5) in lock position. There
must be 0.197 in. (5.00 mm) when locked.
1.70 in.
(4.32 cm)
5
10
0.197 in.
(5.00 mm)
9
END OF WORK PACKAGE