  112    113    114    115    116  117  118    119    120    121    122  
TM 55-1945-205-10-2 0021 00 2 0021 00 GROUND PERSONNEL SHELTER 1. Open exterior hinged cover of electrical shore tie and secure in open position. 2. Connect ground cable (1) to personnel shelter ground stud (2). a. Remove nut (3), lock washer (4) and flat washer (5) from personnel shelter ground stud (2). :,1* b. Using a wire brush, clean ground stud (2) shoulder to ensure that grounding surface has a smooth, bright finish prior to grounding. :,1* c. Apply thin coating of antiseize compound to ground stud (2) base. d. Install ground cable (1) on ground stud (2). 6 7 1 2 3 4 5 9 11 12 8 10 9