TM 55-1945-205-10-2 0003 00 1 0003 00 OPERATOR MAINTENANCE ROLL-ON/ROLL-OFF DISCHARGE FACILITY DESCRIPTION AND DATA LOCATION AND DESCRIPTION OF MAJOR COMPONENTS CENTER MODULE Location The center modules are located between, and attached to, the end rake modules. Description The center module is an empty container. Nominal dimensions of the center module are 8 ft wide, 40 ft long and 4 ft 6 in. deep. Each center module has two 25 ton capacity lifting shackles, which are flush mounted in the deck. The textured deck and smooth bottom are free of any protrusions that might obstruct packing. Access for internal leak detection of each compartment is provided by three recessed threaded plugs. Alternating male and female connectors are equally spaced along both sides and ends of the module. These lock assemblies are stowed flush with the surface and, when deployed, they connect modules with minimum clearance. Weight of the center module is approximately 22,500 lbs. CO NN ECTO R S LIFT SHACKLES CENTER  M ODULE