TM 55-1945-205-10-2 0058 00 2 0058 00 :,1* Keep hands, hair and clothing clear of moving parts. Contact with moving parts may cause serious injury or death to personnel. 2. Remove engine cover. 3. Move lever (1) on primer solenoid to the manual start position. 4. Squeeze fuel primer bulb one time. 5. Move lever (1) on primer solenoid to the run position. 6. Turn ignition key (2) to the on position. 7. Connect emergency stop clip (3) to key switch. 8. Firmly engage fly wheel notch with starter cord knot (4). 9. Wind starter cord (5) clockwise around fly wheel (6). 10.   Starter cord knot (4) must clear starter pinion (7). 11.   Pull lightly on starter cord (5) to remove slack. 12.   Pull hard on starter cord (5) to start motor. 13.   Monitor engine until it slows to a normal idle speed. 14.   Attach safety lanyard clip (8) to operators clothing. END OF WORK PACKAGE 5 7 6 4 RUN M A N U A L START 1 3 2 8