GENERATOR CONTAINER - TM-55-1945-205-10-2_391
GENERATOR CONTAINER (cont)

TM-55-1945-205-10-2 Water Purification Barges NSN (1930-01-234-2165) Volume 9-3 Electric Power System Manual
Page Navigation
  325    326    327    328    329  330  331    332    333    334    335  
TM 55-1945-205-10-2 0078 00 1 0078 00 OPERATOR MAINTENANCE ROLL-ON/ROLL-OFF DISCHARGE FACILITY GENERATOR CONTAINER TROUBLESHOOTING PROCEDURES INITIAL SETUP: Personnel Required Seaman 88K TROUBLESHOOTING PROCEDURE MANUAL FUEL TRANSFER PUMP WILL NOT PRIME SYMPTOM Manuel fuel transfer pump will not prime. MALFUNCTION Fuel supply is depleted from the 1000 gallon fuel tank. CORRECTIVE ACTION Refuel the 1000 gallon fuel tank. (WP 0028 00) MALFUNCTION Transfer pump intake screen clogged. CORRECTIVE ACTION Contact unit maintenance. MALFUNCTION Transfer pump gasket is leaking. CORRECTIVE ACTION Contact unit maintenance. MALFUNCTION Transfer pump vanes or rotors sticking. CORRECTIVE ACTION Contact unit maintenance.