TM 55-1945-205-10-2 0091 00 1/2 blank 0091 00 OPERATOR MAINTENANCE ROLL-ON/ROLL-OFF DISCHARGE FACILITY LIGHT TOWER TROUBLESHOOTING PROCEDURE INITIAL SETUP: Personnel Required Seaman 88K TROUBLESHOOTING PROCEDURE ENGINE SHUTS DOWN SYMPTOM Engine stops running MALFUNCTION Unit out of fuel. CORRECTIVE ACTION Check unit fuel level and refuel. (WP 0114 00) Perform operational check of light tower. (WP 0034 00) MALFUNCTION Engine coolant temperature too high. CORRECTIVE ACTION Check the engine coolant level and add as required. (WP 0114 00) Perform operational check of light tower. (WP 0034 00) MALFUNCTION Engine oil level low. CORRECTIVE ACTION Check the engine oil level and add as required. (WP 0114 00) Perform operational check of light tower. (WP 0034 00) MALFUNCTION Engine fuel filter clogged. CORRECTIVE ACTION Contact unit maintenance. END OF WORK PACKAGE