TM 55-1945-205-10-2 0100 00 1/2 blank 0100 00 OPERATOR MAINTENANCE ROLL-ON/ROLL-OFF DISCHARGE FACILITY LIGHT TOWER TROUBLESHOOTING PROCEDURES INITIAL SETUP: Personnel Required Seaman 88K TROUBLESHOOTING PROCEDURE ENGINE SUDDENLY STOPS SYMPTOM Engine suddenly stopped. MALFUNCTION Unit is low on fuel. CORRECTIVE ACTION Check unit fuel level and refuel. (WP 0114 00) Perform operational check of light tower. (WP 0034 00) MALFUNCTION Engine oil level is low. CORRECTIVE ACTION Inspect and service engine oil system as required. (WP 0114 00) Perform operational check of light tower. (WP 0034 00) MALFUNCTION Engine fuel filter is contaminated with water or debris. CORRECTIVE ACTION Contact unit maintenance. MALFUNCTION Air in the fuel system. CORRECTIVE ACTION Contact unit maintenance. END OF WORK PACKAGE