TM 55-1945-205-10-2
0114 00 19
0114 00
12
Before
.3
Rigid Hull
Inflatable Boat
(Contd)
a. Check battery electrolyte
level. Fill with distilled water to
3/16 inch above cell plates.
Battery is
inoperative.
b. Ensure all battery cable
clamps and hold downs are tight.
Make sure all are secure and free
of corrosion. Tighten and clean
if necessary. If battery clamps or
holdowns are loose or corroded,
contact unit maintenance.
Battery is
inoperative.
5. Check steering hydraulic lines
for leakage. If oil leaks are found,
contact unit maintenance.
Class III oil leakage
is found.
6. Check propeller for damage. If
propeller damage is found, contact
unit maintenance
7. Turn key to ON position for
powered checks.
a. Check gage indication. All
gauge warning lights should
illuminate and warning horn
should sound. If gage warning
lights do not illuminate or
warning horn does not sound,
contact unit maintenance
Table 1. Preventive Maintenance Checks and Services. (Continued)
ITEM
NO.
INTERVAL
MAN-
HOURS
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
2
RPM
x1000
0
1
3
4
5
6
7
NO
OILHOT
CHK
ENG
LOW
OIL