TM 55-1945-205-10-4
0032 00 2
0032 00
2.
Position MAIN BREAKER (3) to off (down) position.
3.
Position LAMP switches (4), (5), (6) and (7), to off (down) position.
&,21
Do not use ether in conjunction with the glow plug preheat system. Failure to comply
will result in engine damage.
4.
Turn rotary switch (8) to PRE HEAT for 5 seconds prior to starting.
&,21
Do not crank for more than 15 seconds without allowing starter to cool for 30
seconds. Failure to comply could result in starter damage.
5.
After 5 seconds, turn rotary switch (8) to START.
&,21
Keep side doors closed for optimum cooling of unit while running. Failure to comply
could result in engine damage.
6.
Release rotary switch (8) after engine continues to run.
7.
Allow engine to run for 3 to 5 minutes before using RECEPTACLES (1) and (2) and LAMP switches (4),
(5), (6) and (7).
8.
If engine stops unexpectedly, refer to troubleshooting procedures.
9.
Plug external loads into RECEPTACLES (1) and (2), as required.
10. Position MAIN BREAKER (3) to the on (up) position.
11. Position LAMP SWITCHES (4), (5), (6) and (7) to on (up) positions, as required.
H O U R M E T E R
O FF
RU N
STAR T
PR E
H EAT
FUEL LEVEL
M AIN
BREAKER
RECEPTACLE
120 V 20A
RECEPTACLE
240 V 20A
PUSH TO
RESET
LAM P
2
LAM P
1
LAM P
4
LAM P
3
7
5
1
2
6
4
8
3