TM 55-1945-205-24-2
0242 00 3
0242 00
WARNING
9.
Tilt end of tube (11) and drain hydraulic fluid into drain pan.
10. Remove hydraulic metal tube (11) and discard.
WARNING
11. Remove drain pan and dispose of hydraulic fluid in accordance with local procedures.
INSTALL LIFT HYDRAULIC METAL TUBE FROM LIFT HYDRAULIC PUMP TO
BULKHEAD ADAPTOR
1.
Using cloth, wipe fittings.
2.
Position new tube (11) on bulkhead adaptor (10).
3.
Connect fitting (9) to bulkhead adaptor (10). Tighten fitting (9).
4.
Install three mounting clamps (7) on tube (11).
5.
Position three mounting clamps (7) on mounting bosses (8).
6.
Install three bolts (6), lock washers (5) and nuts (4) in mounting clamps (7). Tighten bolts (6).
7.
Connect fitting (3) to hydraulic pump (1). Tighten fitting (3).
8.
Rotate release valve (2) clockwise.
9.
Service EASY container hydraulic system. (WP 0233 00)
WARNING
10. Pump handle (12) until lift table (13) is fully elevated.
11. Rotate relief valve (2) counterclockwise.