TM 5-1940-277-34
ALTERNATOR REPAIR INSTRUCTIONS
(Continued)
LOCATION
ITEM
ACTION
REMARKS
12.
Slip ring end
Diodes
a. Test diodes
Use multimeter
shield (26)
for service-
TS-352B/U.
ability using
Diodes can be
following
tested while the
table:
three heat sinks
are still assem-
bled in the end
shield.
Position of Test Probes
Needle
Test
Positive Probe
Negative Probe
Indication
1
Each heat
Terminal +
To Full Right
sink in turn
(Continuity)
2
Terminal +
Each heat
No Movement
sink in turn
(Open Circuit)
3
Terminal -
Each heat
To Full Right
sink in turn
(Continuity)
4
Each heat
Terminal -
No Movement
sink in turn
(Open Circuit)
5
Each heat
'A' lead
To Full Right
sink in turn
(Continuity)
6
'A' lead
Each heat
No Movement
sink in turn
(Open Circuit)
b.
Replace heat
sinks and end
shields as a
unit if any
indication is
incorrect.
2-75