TM 5-5420-202-20-1
P r e v e n t i v e Maintenance Checks and Services for M60A1 AVLB Hull -
Continued
Location
Not Fully Mission
Procedure
Item to
Interval
Capable if:
Check/Service
No.
Set engine speed at 1600 rpm.
Engine Smoke
17
Semiannual
Generator (If
equipped)
Lift toggle switch safety cover. Place
position. Check that indicator lamp
lights.
Have commander check for smoke
emission from engine exhaust pipes.
Smoke is not ob-
If smoke is not observed within 10
served within 10
seconds, system is defective. Place
seconds.
OFF position.
C h a n g e 4 3-23