TM
5-5420-202-20-2
Using spanner wrench, disconnect four electrical harness connectors (M) at both sides
12.
o f powerplant.
Using screwdriver, loosen two clamps (N) which hold air cleaner outlet hose (P) at each
13.
Disconnect air cleaner outlet hoses (P).
14.
Make sure you cover air cleaner outlet hose
openings.
NOTE
If your vehicle is equipped with a
2DA engine, do steps 14.1 and 14.2.
If not, proceed to step 15.
14.1
Using screwdriver, loosen two clamps
(P.1).
14.2.
Slide hose (P.2) off manifold (P.3) and
back onto tube (P.4).
Go on to Sheet 5
Change 1
5-5