TM 5-5420-209-12
Table 4-3. Unit Preventive Maintenance Checks and services (PMCS) for the interior Bay cont.
Item
Interval
Location
Item to
Item To Be Inspected
Equipment Is Not
Service/Check
Procedure
Ready/Available If
39
Monthly Lower Lock
Inspect screw and threads for cracks, burrs,
Screw will not extend or
Drive
nicks and deformation.
retract drive pin properly.
Inspect trunions, and drive pin for cracks.
Cracks or broken welds
Inspect cover bumpers and supports for
noted.
broken welds and deformation.
40
Monthly
Support Links
Inspect for broken welds, cracks and
Broken welds noted.
deformation.
41
Monthly
Lifting Eye
Inspect for cracks and elongation of eye.
Any cracks noted or eye
(Rear)
elongation equals 25%
of original
circumference.
NOTE
Cable, when adjusted
correctly, will be taut NOT
tight.
42
Monthly Unfolding Cable Check cable adjustment.
Cable out of adjustment.
Assembly
Inspect for kinks, frayed or broken strands,
Kinks frayed, broken,
compressed or flat areas.
compressed of flat
surface areas noted.
43
Monthly Cable Guide
Inspect for cracks, gouges, jagged protrusions,
Eye cracked, elongated
erosion or surface area and elongation of eye.
more than 0.50 at upper
arc or aluminum eroded
to within .050.
44
Monthly Unfolding Cable Check cable adjustment.
Cable out of adjustment.
Assembly
Inspect for kinks, frayed or broken strands,
Kinks frayed, broken,
compressed or flat areas.
compressed of flat
surface areas noted.
45
Monthly
Lower Lock
Inspect screw and threads for cracks, burrs,
Screw will not extend or
Drive
nicks and deformation.
retract drive pin properly.
Inspect trunions, and drive pin for cracks.
Cracks or broken welds
Inspect cover bumpers and supports for
noted.
broken welds and deformation.
NOTE
To inspect the following items
properly, bay must be
unfolded (on ground or in
water).
4-23
No.