4-26. Walkways.-Continued
NOTE
Walkways removed for repair. See para. a above.
b. Repair. (figure 4-14)
WARNING
Dry cleaning solvent PD-680 used to clean parts is potentially dangerous to personnel and property.
Avoid repeated and prolonged skin contact. Do not use near open flame or excessive heat. Flash point
of solvent is 100-138°F (38-60°C).
(1) Clean walkway (1) with dry cleaning solvent, and dry thoroughly.
(2)
Inspect walkway (1) and repair all cracks, tears, holes or broken welds by welding.
(3) Straighten walkway using an approved sheet metal maintenance procedure.
(4) Apply non-slip deck covering as required.
(5) Spot paint as required.
(6) Install walkway (para. a above).
4-62
TM 5-5420-209-12