447. Single Over Center Valve. - Continued
b. Adjust. (figure 4-57)
Adjust Single over center valve as follows: Adjust overload relief valve so that hydraulic flow between cylinder relief
pressure port and valve port is at 2,400 psi (25,548 kpa). Full flow 20 gpm (75.6 pm) should occur at 2,600 psi
(182,980 kpa).
4-178