4-48. Cable Tensioner Valve (Transporter Model RBT). - Continued(7)(8)(9)(10)(11)(12)Connect 0-1,000 psi (0-6,895 kpa) hydraulic pressure source to M1.Connect hydraulic fluid reservoir to P1.Plug S1 and S2.NOTETemperature of hydraulic oil should be 86-104°F (30-40 °C).Adjust fluid flow to 13 gpm (49 Lpm).Check gage at G and verify that valve A opens between 580-726 psi (3,999-4,986 kpa). Adjust valve A ifvalve does not open within limits, see Pam. b. below.Set all pressures to 0 psi (0 kpa) and disconnect all connections.TM 5-5420-209-124-184