4-48. Cable Tensioner Valve (Transporter Model RBT). - Continued
(7)
(8)
(9)
(10)
(11)
(12)
Connect 0-1,000 psi (0-6,895 kpa) hydraulic pressure source to M1.
Connect hydraulic fluid reservoir to P1.
Plug S1 and S2.
NOTE
Temperature of hydraulic oil should be 86-104°F (30-40 °C).
Adjust fluid flow to 13 gpm (49 Lpm).
Check gage at G and verify that valve A opens between 580-726 psi (3,999-4,986 kpa). Adjust valve A if
valve does not open within limits, see Pam. b. below.
Set all pressures to 0 psi (0 kpa) and disconnect all connections.
TM 5-5420-209-12