4-75. Latch Receptacle and Strike Catch. - Continued
b. Replace. (figure 4-99)
NOTE
The replace procedures are the same for all latch receptacles.
(1) Remove four nuts (1), lockwashers (2), screws(3), latch receptacle (4) and shim (5).
(2) Remove four nuts (6), lockwashers (7), screws (8), strike catch (9) and shim (10).
(3) Install shim (10), strike latch (9), and secure with fourscrews (8), lockwashers (7), and nuts (6).
(4) Install shim (5) and receptacle (4), and secure with four screws(3), lockwasher (2), and
nuts (1).
(5) Adjust receptacles.
4-258
TM 5-5420-209-12