• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
INSTRUMENT PANEL CLUSTER ASSEMBLY REPAIR - Continued
INSTRUMENT PANEL CLUSTER ASSEMBLY REPAIR - Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  131    132    133    134    135  136  137    138    139    140    141  
img
TM 5-5420-226 -20-3
lNSTRUMENT PANEL CLUSTER ASSEMBLY REPAIR (Sheet 21 of 23)
Instrument Panel Wiring Harness- Replacement ( 3 of 4)
10. Disconnect two leads (circuit 40) from two
panel lights (M).
11. Loosen receptacle connector retainer nut
(N) hidden and slide back on leads.
12. Remove wiring harness from panel.
INSTALLATION
1. Apply silicone compound to sixteen lead
connectors of instrument panel wiring
harness.
2. Place wiring harness in position in panel.
3. Using fingers, tighten receptacle connec-
tor retainer nut (A) (hidden) to
receptacle connector (B).
4. Using screwdriver, install four screws and
lockwashers (C) securing receptacle con-
nector (B) to panel.
5. Using wrench, install nut and lockwasher
(D) securing harness junction (E) to panel.
Go on to Sheet 4